1-20ml Ampoule Washing, Drying and Filling Production Line

1-20ml Ampoule Washing, Drying and Filling Production Line

Model No.︰AGF

Brand Name︰SHPM

Country of Origin︰-

Unit Price︰US $ 153450 / set

Minimum Order︰1 set

Inquire Now

Product Description

 

1-20ml Ampoule Washing, Drying and Filling Production Line

 

This machine consists of Model ACQ-II Ultrasonic Type Washing machine, Model GMSU-400C Tunnel Type Bacterium Killing Oven, Model AGF6-Ampoule Wire-drawing Filling and Sealing Machine, Model GG Supply Water Filtering Device and 100-stage laminar flow purifying.

No.1 Working Principle:

Putting the tray full of ampoules into the ACQ-II Ultrasonic Type Washing Machine , it will spray water automatically. When the start-up sing is displayed, press the PLC control button. The tray will be immersed into water, and the ampoules will be fed into a position between the ultrasonic transducer under the action of a tray-pushing cylinder and washed by ultrasonic ware for about 1minute (time can be adjusted). Then the trap enters a disk and turn over for 180o, and then, the ampoules leave the water with their mouths downward, then they are put into internal spraying and external drenching station under the drive of top tray cylinder, external wall of bottles are drenched and internal wall of bottles are sprayed and washed by water and gas in three times circle-washing (washing time and times be set according to actual production requirements.) After above procedure is finished, bottles are rushed with gas to remove residual water, then with draw automatically. After that, the ampoules are conveyed into the tunnel of oven by the manual turn bottles.

Under the monitoring of intelligent system of GMSU-400C Tunnel Type Bacterium Killing Oven, bottle are fed into preheating zone, high temperature killing bacterium zone (temperature is 350c); bacterium killing time is ?Y5 min) and low temperature zone of tunnel bacterium killing oven. The speed of chain is stepless adjustable. It has paper recording or non-paper recording in temperature control system. Whole operating process always under the protection of 100-stage laminar flow.It is dry and non-bacterium after cooling. The ampoules, which have been removed heat, are taken out manually, then into the Filling and Sealing machine to fill and seal.

Ampoule-bottles are put into passage for bottle entrance in bulk by the transmission belt of AGF model 6-ampoule filling and sealing machine, under the control of barrier six ampoule-bottles are segregated every time, then carried to filling unit and stealing by teeth-plate in interval. The filling and stealing is under the protect of one hundred stage lamina flow. Sealed ampoule-bottle is put outside bottle-pusher.

 

No.2 Main Technical Specification:

1.Ultrasonic type ampoule(bottle) washing machine

1). Air pressure :0. 35-0.45mpa

2). Water 0.3-0.4mpa

3). Voltage: 380v 50Hz

4). Electric power: 3kw

5).Qualifying rate of clear degree :¨R97%

6).Breaking rate of Ampoule (bottle):?ü1%

7).Noise :?ü70 dB

8). Water consumption: 10 liter per plate (2ml ampoule)

9). Air consumption: 1.2m3/min

10). Overall (L X W X H): 3350X700X1700 

2.AGF Ampoule Wire-drawing Filling and Sealing Machine

Filling heads

6 heads

8heads

Capacity

1~2ml

16000pcs/h

21000pcs/h

5ml

12000pcs/h

16000pcs/h

10ml

8000pcs/h

11000pcs/h

20ml

4500pcs/h

6000pcs/h

Nitrogen consumption

1.5m3/h

2m3/h

Fuel gas consumption

City gas

1.5m3/h

2m3/h

Liquefied gas

0.3 m3/h

0.4m3/h

Oxygen consumption

For city gas

0.9m3/h

1.2m3/h

For liquefied gas

1.3m3/h

1.7m3/h

Air intake requirement

0.6m/s

0.6m/s

Power consumption

2kw

2kw

  • Power: 380V, 50Hz
  • Gross power of motor: 1.5kw
  • Volume of liquid gas: 1.2m3/h
  • Volume of oxygen gas: 0.6m3/h
  • Speed control: 30 ~ 36 r/min (staples speed adjustment).
  • Weight: about 1400kg
  • Overall size (length * width * height): 2500*1200*2250m

3. Tunnel Type Bacterium Killing Oven

  • Power: 380V, 50HZ
  • Installation Power: 30kw
  • Scope of temperature adjustment: 100-350oC
  • Lamina flow purifying stage: 100stage
  • Cooling method: one hundred vertical laminar flow cooling
  • Air volume of purified blower fan: 2250-3370m3/h

Wind Pressure: 200-300pa

  • Control of wind speed: in frequency conversion
  • Noise: ?ü79dB
  • Transmission method: in chain
  • Conveying speed: 100-220mm/min (non-stage adjustment speed)
  • Weight: 2200kg
  • Overall size: 3910(4880, 6000)*1220*2050(mm) (L*W*H)
  • Working condition: in room temperature rate in the: 10-15pa

 

Product Image